Part Number Hot Search : 
5M250 010006 AS1153 74A250 XC21651 EMK31 30F10 SF1010
Product Description
Full Text Search
 

To Download SR036DB1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 SR036DB1 Inductorless Switching Power Supply
Introduction
The Supertex SR036 is an inductorless, dual output off-line regulator intended for 120/240VAC line operation. The operating principle is to activate a pass element between line and load only when the input voltage is lower than a certain value. Thus conduction only occurs with a low voltage drop across the pass element, resulting in more efficient operation compared to a standard linear regulator. The SR036DB1 demo board contains all the circuitry needed to supply a low-current (<40mA) load. Included are input protection circuitry, a full wave bridge rectifier, a pass element, and output capacitors.
Specifications
AC Input Output Voltages VUNREG VREG Output Current IUNREG + IREG Efficiency
ACIN=120VAC 60Hz, IU=40mA, IR=0mA
24VAC to 264VAC 40Hz to 100Hz 18V20% 3.3V 10% 40mA @ 120VAC 30mA @ 240VAC 40% typ
Board Layout and Connections
Q1 Z1 ACIN F1 D1 IC1 C2 C1
GND WARNING!!! Do not connect to scope ground or to the ground of other earth-grounded instruments. Doing so will short the AC line, resulting in damage to the circuit and/or instrument. Either use an isolation transformer on the AC line, use a differential probe, or use a floating, battery-powered instrument to make measurements.
VREG
VUNREG
WARNING!!! No galvanic isolation. Dangerous voltages are present when connected to the AC mains.
ACIN Connect to the AC line. Neutral to top, hot to bottom.
VUNREG The unregulated output. Nominal output voltage is 18 volts. This output will have a certain amount of 120Hz ripple, depending on load. Do not connect to earth-grounded loads.
GND Circuit common. Note that since galvanic isolation is not provided, connecting this point to an earth-grounded instrument (such as an oscilloscope) will short the AC line, resulting in circuit and/or instrument damage. Also note that GND may be at a higher potential with respect to earth ground, even if the AC is switched off. Use caution! Do not connect to earth-ground.
VREG The regulated output. 5V nominal output voltage. Do not connect to earth-grounded loads.
Fuse The AC input is fused to protect against overloads. It should be replaced with a 125mA, 250V standard 3AG fuse.
16APR02
1
SR036DB1 Inductorless Switching Power Supply
SR036 Circuit
F1 125mA D1 ACIN Z1 P6KE400CA Q1 VN2460N8
VUNREG C1 220F
IC1 SR036
VREG C2 1F
Parts List
Desig F1 Z1 D1 IC1 Q1 C1 C2 Description Fuse, 3AG, 125mA, 250V Transient voltage suppressor, 400V Diode bridge, 1A, 600V HV Supply Controller MOSFET, 600V N-channel Capacitor, alum, 220F, 35V Capacitor, cer, 1F, 16V Supertex SR036SG Supertex VN2460N8 P6KE400CA Part Number
Modifications
The SR036DB1 may be modified to provide higher output current. Remove Q1 and replace with a D-Pak N-channel MOSFET with a voltage rating appropriate for the input voltage. The on resistance of the replacement FET is not as important as the gate threshold voltage - the lower the threshold voltage, the more efficient the converter. To reduce ripple at the higher output current, C1 may be replaced with a higher value capacitor.
16APR02
2


▲Up To Search▲   

 
Price & Availability of SR036DB1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X